hotun one - Multiple Condensate Pipe Hopper

Used To Receive Multiple 21.5mm FCU/MVHR/Overflow Condensate Discharge Pipes

PATENTED, PIONEERING PRODUCTS 

A versatile tundish hopper for multiple condensate discharge applications.

The hotun one hopper is an unique, purpose-built hopper accessory that simplifies the management of multiple drainage lines. It enables installers a more practical option for connecting and managing multiple 21.5mm overflow condensate discharge pipes.

Connect Up To Three Discharge Pipes

Instead of running seperate pipes into individual connections, the hotun one hopper serves as a central collection point that lets you neatly feed up to three seperate 21.5mm overflow or condensate pipes into a single hotun dry trap tundish, helping to simplify drainage arrangements and reduces pipework clutter, resulting in a more organised installation.

Compact Design For Space-Limited Installations

The hotun One Hopper is a small solution for installations with limited space, measuring only 60 x 22mm. It is especially helpful for handling overflow and condensate pipework from FCUs and MVHR units because of its thin design, which facilitates the consolidation of multiple discharge lines.

Compatible hotun Dry Trap Tundishes

The hotun one hopper, which is intended to be used in conjunction with the hotun dry trap tundishes, offers a practical means of connecting several discharge lines. It helps create a neat and space efficient drainage solution and is especially well suited for installations that use the hotun DTCSF dry trap tundish.

Explore The hotun Product Range

Discover the wider range of hotun products, designed to improve safety, enhance system protection and provide reliable solutions for unvented hot water systems. Explore our range to find the right product for your installation.

Key Product Information

About hotun one Dry Trap Tundish Hopper

Key product information at a glance.

Key Features & Benefits

  • Compatible with hotun 100c & hotun SF range of tundishes, but specifically designed for use with hotun DTCSF.
  • Enables multiple line routing into a single drop trap tundish
  • Designed for linited space installations
  • Suitable for receiving multiple 21.5mm discharge pipes from:
    • FCU’s (Fan Coil Unit’s)
    • MVHR’s (Mechanical Ventilation with Heat Recovery)
    • Overflow condensates

      Click either image to enlarge in a new page


       

       Product Name

       hotun one

       Product Type

       Tundish hopper

       MPN

       HW-ONE 60×22

       Open Inlet

       60mm

       Maximum Inlet Pipes

       3

       Compatible Inlet Pipes 

       22mm copper / 21.5mm plastic 

       Outlet

       22mm

       Outlet Connection

       compression nut and olive supplied

       Application

      • FCU’s (Fan Coil Unit’s)
      • MVHR’s (Mechanical Ventilation with Heat Recovery)
      • Overflow condensates

       

      10 Year Standard Warranty*

      RA Tech UK Ltd provides a 10 Year Conditional Warranty, the installer must register the product within 14 days of the installation date. Failure to register the product and carry out the annual service may invalidate the warranty.

      A copy of the Installation Commissioning and Warranty Instructions MI 2024 v1.3a and Commissioning Record must be filled out and a copy returned to RA Tech UK Ltd at time of installation, or the registration form found here, must be filled out and submitted from our website within 14 days of the installation date.

      If you have multiple installations on a single project, you can group the entire installation into one project application

      In subsequent years, the tundish must have the annual service checks and subsequent service records filled out by a competent engineer, to continue to validate the conditional warranty.

      When installed in compliance with the installation instructions, is registered and has all of its relevant annual service checks, all hotun dry trap tundishes are warranted for a period of 10 years for any manufacturing fault or defect.

      The customer should be given the signed “Installation, Commissioning and Service Records” found on the installation leaflet at the completion of the installation.

      Please follow this link to download a printable copy of the hotun range installation, operation, service and warranty instructions

      In the unlikely event that the product develops a manufacturing fault during this period, in the first instance, please send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the issue with the product, or call us on 01332 702678.

      To register your hotun detect alarm unit, please fill out our online registration form here

      Warranty Claims Procedure

      If you think you have a faulty product, please fill out our hotun detect Warranty Claims Form or send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim hotun detect” stating the date of purchase (with proof) and let us know what has gone wrong. Alternatively, you could call us on (01332) 702678 and speak to one of our team.

      *(if registered – conditions apply)

      Downloads & Information

      Everything You Need

      Product information, technical data and installation examples all in one place.

      Point Of Sale Leaflet

      Download PDF

      Product Guide

      Download PDF

      Featured Installations

      View Projects

      You May Also Like

      Customers Also Bought

      Other popular hotun products trusted by installers across the UK.

      Product Selector Guide

      Discover The Right hotun Solution For Your Requirements

      Use the product selector to quickly identify the most suitable hotun solution for your application.

      1. Select your installation type
      Choose the option that best matches your boiler or heating system.

      2. Select the required temperature
      This helps determine which hotun product is suitable for your installation.

      3. View your recommended product
      The selector will guide you towards the appropriate product and provide further information.

      Need help choosing?
      If you’re unsure which product you need, contact our technical team for assistance.

      Question 1

      What are you looking for?

      Select the option that best describes what you need.

      Question 2

      What system is the tundish being used with?

      This helps us identify the appropriate tundish range.

      Question 3

      What connection size do you require?

      Choose the connection size, or select unsure if you need help identifying it.

      Question 2

      Where do you want the discharge alarm?

      Choose where you want the alarm to be heard.

      Question 3

      Would you like detection at the installation as well?

      hotun detect provides audible and visual indication of water discharge.

      Question 2

      Which protection do you require?

      Select the application or range you are working with.

      Question 3

      Would you like discharge detection too?

      Add hotun detect to provide audible and visual warning of water discharge.

      Question 2

      How many discharge pipes are you connecting?

      This helps identify the appropriate condensate solution.

      Question 3

      Would you like discharge detection too?

      Add hotun detect if you want audible and visual warning of water discharge.

      Your result

      Your recommended hotun solution

      Based on your answers, the following hotun products form the suggested solution for your installation.

      Recommended hotun products

      Find your nearest hotun stockist

      Enter your postcode and we'll take you straight to the hotun Store Locator.

      Please enter your postcode.