hotun NV 100c 15x22mm Standard Tundish

A Wider Standard Tundish Designed For Higher Flow Rates

hotun NV product image

PATENTED, PIONEERING PRODUCTS 

The original hotun was more than just a tundish – now we offer a standard tundish!

The hotun NV 100c is a 15mm x 22mm standard tundish designed to accommodate higher discharge flow rates than conventional narrow tundishes.

Its wider internal design provides greater capacity to handle water discharged from pressure relief valves (PRVs) and combined temperature and pressure relief valves (T/PRVs), helping to reduce the risk of water overflowing during discharge.

Featuring an open-sided design, the hotun NV 100c allows installers and property owners to clearly observe both flowing and residual water, providing an important visual indication of potential system faults.

Why Choose The hotun NV 100c?

On all sealed heating and hot water systems, it’s mandatory for any water passing from the safety device (either a combined Temperature and Pressure Relief Valve (T/PRV) or Pressure Relief Valve (PRV)), to be conveyed to a place where any passing water can be observed and discharged safely, and doesn’t cause danger to a person or building.

A standard tundish provides an industry-acceptable way of allowing water to be observed from within the building. It gives the occupiers a way of seeing the water. Using this as a warning something could be wrong with the system (Under normal operating conditions, water does not pass out of the PRV).

Easy Cleaning and Maintenance

The hotun NV 100c tundish can be cleaned easily while remaining in situ. This means that you do not need to remove or dismantle the unit for routine maintenance.

Standard Tundish vs Dry Trap Tundish?

Not sure what the difference is between a standard tundish and a dry trap tundish? Understanding how they work and the benefits of each can help you choose the right solution for your installation. Our guide explains the key differences, including how an integrated dry trap helps prevent foul air and unwanted odours from entering your property through the drainage system.

Read our guide: What is a tundish? 

Key Product Information

About hotun NV 100c Tundish 

Key product information at a glance.

       MPN

       Black – HBNV 100C 15×22

       White – HWNV 100C 15×22

       Inlet Pipe Size

       15mm (or 1/2″ for imperial applications)

       Inlet Connection

       15mm Compression nut and olive (supplied)

       Outlet Pipe Size

       22mm Copper or 21.5mm plastic

       Outlet Connection

       22mm Compression nut and olive (supplied)

       Application

      • Any relief valve discharge

       

      10 Year Conditional Warranty*

      RA Tech UK Ltd provides a 10 Year Conditional Warranty, the installer must register the product within 14 days of the installation date. Failure to register the product and carry out the annual service may invalidate the warranty.

      A copy of the Installation Commissioning and Warranty Instructions MI 2024 v1.3a and Commissioning Record must be filled out and a copy returned to RA Tech UK Ltd at time of installation, or the registration form found here, must be filled out and submitted from our website within 14 days of the installation date.

      If you have multiple installations on a single project, you can group the entire installation into one project application

      In subsequent years, the tundish must have the annual service checks and subsequent service records filled out by a competent engineer, to continue to validate the conditional warranty.

      When installed in compliance with the installation instructions, is registered and has all of its relevant annual service checks, all hotun tundishes are warranted for a period of 10 years for any manufacturing fault or defect.

      The customer should be given the signed “Installation, Commissioning and Service Records” found on the installation leaflet at the completion of the installation.

      Please follow this link to download a printable copy of the hotun range installation, operation, service and warranty instructions

      In the unlikely event that the product develops a manufacturing fault during this period, in the first instance, please send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the issue with the product, or call us on 01332 702678.

      Warranty Claims Procedure

      If you think you have a faulty product, please fill out our Warranty Claims Form or send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the date of purchase (with proof) and let us know what has gone wrong. Alternatively, you could call us on (01332) 702678 and speak to one of our team.

      *(if registered – conditions apply)

      WRAS Approved product

      hotun nv 100C  is WRAS approved –

      WRAS Approval Number: 240504701

       

      Downloads & Information

      Everything You Need

      Product information, technical data and installation examples all in one place.

      Point Of Sale Leaflet

      Download PDF

      Product Guide

      Download PDF

      Featured Installations

      View Projects

      You May Also Like

      Customers Also Bought

      Other popular hotun products trusted by installers across the UK.

      Product Resources

      Downloadable Images

      Download high-quality product images.

      Product Selector Guide

      Discover The Right hotun Solution For Your Requirements

      Use the product selector to quickly identify the most suitable hotun solution for your application.

      1. Select your installation type
      Choose the option that best matches your boiler or heating system.

      2. Select the required temperature
      This helps determine which hotun product is suitable for your installation.

      3. View your recommended product
      The selector will guide you towards the appropriate product and provide further information.

      Need help choosing?
      If you’re unsure which product you need, contact our technical team for assistance.

      Question 1

      What are you looking for?

      Select the option that best describes what you need.

      Question 2

      What system is the tundish being used with?

      This helps us identify the appropriate tundish range.

      Question 3

      What connection size do you require?

      Choose the connection size, or select unsure if you need help identifying it.

      Question 2

      Where do you want the discharge alarm?

      Choose where you want the alarm to be heard.

      Question 3

      Would you like detection at the installation as well?

      hotun detect provides audible and visual indication of water discharge.

      Question 2

      Which protection do you require?

      Select the application or range you are working with.

      Question 3

      Would you like discharge detection too?

      Add hotun detect to provide audible and visual warning of water discharge.

      Question 2

      How many discharge pipes are you connecting?

      This helps identify the appropriate condensate solution.

      Question 3

      Would you like discharge detection too?

      Add hotun detect if you want audible and visual warning of water discharge.

      Your result

      Your recommended hotun solution

      Based on your answers, the following hotun products form the suggested solution for your installation.

      Recommended hotun products

      Find your nearest hotun stockist

      Enter your postcode and we'll take you straight to the hotun Store Locator.

      Please enter your postcode.