hotun hiflo 15x32mm SF Dry Trap Tundish

High-Flow Push-Fit Dry Trap Protection

PATENTED, PIONEERING PRODUCTS 

High-flow dry trap protection for demanding discharge applications.

The hotun hiflo SF 15x32mm dry trap tundish combines a high-flow tundish with an integrated dry trap, providing a safe and visible way to discharge water from temperature and pressure relief valves (T/PRVs) into a soil pipe. Designed for applications requiring a higher discharge capacity, it offers reliable dry trap protection for boilers and unvented water heating systems.

Featuring a 15mm speedfit push-fit inlet and 32mm outlet connection, the hotun hiflo SF is designed for installations requiring increased discharge capacity and reliable dry trap protection.

With a rated flow rate of 25 litres per minute (LPM) and a maximum flow rate of 45 LPM when installed with optimised pipework, the hotun hiflo SF is a practical solution for high-volume discharge applications.

hotun detect PRV Alarm Range Compatibility

The hotun hiflo SF 15x32mm dry trap tundish is compatible with both the hotun detect and hotun detect remote alarm systems. These products help identify water dripping or flowing from a system’s relief valve through the tundish, alerting users to potential faults that may require investigation and remedial action.

The hotun detect alarm unit provides audible and visual alerts, while hotun detect remote allows alerts to be received in a more accessible location. This is particularly useful when the tundish is installed in a concealed or hard-to-reach area.

Together, these products make it easier to identify water discharge and investigate potential issues promptly, helping to reduce unnecessary water and energy waste.

Suitable Applications

The hotun hiflo SF is designed for compatible installations requiring higher discharge flow rates, including:

  • Unvented water heaters fitted with combined temperature and pressure relief valves (T/PRVs), up to the rated flow rate.
  • Boilers.
  • HIUs (Heat Interface Units).
  • FCU and MVHR drip trays and water tank overflows, where suitable for the application.

Installation and Compliance Considerations

For unvented water heaters fitted with T/PRVs, all downstream D2 discharge pipework and soil pipes must be suitably rated for water discharging at temperatures of 90–95°C.

Appliances fitted with pressure relief valves (PRVs) only, such as boilers and water heaters with a capacity below 15 litres, do not have the same D2 waste pipe temperature requirement.

For the best flow performance, ensure the pipework is optimised in line with the manufacturer’s installation guidance. Always check that the selected connections, discharge pipework and overall installation are suitable for the specific system.

 View all products in the hotun SF range here

 

 

Key Product Information

About hotun hiflo SF Dry Trap Tundish 

Key product information at a glance.

Key Features

  • Approved under WRAS Approval Number 250404708, supporting compliance with relevant water regulations.
  • Unique open-sided design allows visibility of both flowing and residual water, helping with fault diagnosis and routine inspection.
  • Easy maintenance due to it being able to be inspected and cleaned in situ without removing or dismantling the tundish.
  • Compatible with hotun detect and hotun detect remote. Supports discharge monitoring with an audible alarm to help identify potential PRV discharge issues, including where remote notification is useful.
  • Features an A2 stainless steel spring and bolt, plus a high-quality, moulded drainage-grade EPDM rubber valve.
  • Developed to meet relevant Water and Building Regulation requirements when installed in accordance with the manufacturer’s instructions.
  • High-flow performance rated to 25 LPM, with a maximum flow rate of 45 LPM under optimised installation conditions.
  • Integrated dry trap combining a tundish and dry trap in one unit.
  • Features a 15mm temperature compliant push-fit inlet connection.
  • Suitable for 32mm or 1¼-inch push-fit connections or compatible universal mechanical fittings.
  • Suitable for boilers, unvented water heaters and other compatible high-volume discharge applications.

    Key Benefits

    • Long-term reassurance with a 10 year conditional warranty when installed and maintained in accordance with the warranty terms.
    • Helps prevent foul smells from the waste system entering the building while allowing visible discharge from the relief valve.

        The 1 1/4″ (32mm) outlet on the hiflo version is compatible with either universal compression or push-fit fittings.

        Due to the material used in hotun plastic (acetyl) it will not successfully solvent weld, and due to its size, female solvent weld fittings will be too large for the male spigot.

        It must also be noted that many solvent weld pipes are not of a sufficient grade (material) and are therefore not suitable to be used in unvented hot water heater D2 discharges when connected to a TEMPERATURE RELIEF VALVE discharge line*.

        *NB – this note about the suitability of pipework materials is only relevant to applications that have a TEMPERATURE RELIEF VALVE operating at temperatures above 90°C over several cycles of flow.

        For all applications that have a pressure relief valve only (eg boilers and small unvented water heaters) the issue of temperature and volume of water is not an issue and a much wider range of materials will be suitable for use.

        If you are unsure of these requirements please feel free to contact our technical team on our contact us page and we will be able to fully discuss these issues with you.

        Click either image to enlarge in a new page

        Typical boiler pipework configuration connected to condensate discharge

        Recommended-installation-diagram-showing-position-of-hotun-undereath-the-boiler-along-with-combined-D2-with-codensate-into-a-single-pipe-solution

        Typical small unvented pipework configuration

        Diagram of Typical pipework arrangement when using a hotun dry-trap tundish with a small unvented water heater

        Typical large unvented pipework configuration
        Diagram of compliant installation of a tundish and pressure relief valve on an unvented water heater

         

        Diagram showing typical Large Unvented T/PRV into hotun tundish to soil pipe arrangement

         Inlet Pipe Size

         15mm (or 1/2″ for imperial applications)

         Inlet Connection

         15mm Inbuilt temperature compliant push-fit connection

         Outlet Pipe Size

         32mm – (1 1/4″ equivalent)

         Outlet Connection

         Suitable for 32mm or 1 1/4″push fit or universal mechanical fittings – see compatible connection   diagrams below  –  (hotun hiflo SF outlet size is not compatible with solvent weld fittings)

         Rated Flow Rate

         25LPM

         Max Flow Rate

         45LPM (with optimised pipework – 200mm straight pipe before tundish see optimised diagrams below)

         Usual Applications

        • Any/all unvented water heaters with combined T/PRV’s up to the rated flow rate.
        • Boilers
        • HIUs

        NB

        1. For unvented water heaters fitted with T/PRV’s, all D2 downstream pipework and soil pipes must be suitably rated for water discharging at 90-95°C.

        2. Appliances with PRV’s only (ie boilers and water heaters of less than 15L capacity) do not have a D2 waste pipe temperature requirement

        10 Year Conditional Warranty*

        RA Tech UK Ltd provides a 10 Year Conditional Warranty, the installer must register the product within 14 days of the installation date. Failure to register the product and carry out the annual service may invalidate the warranty.

        A copy of the Installation Commissioning and Warranty Instructions MI 2024 v1.3a and Commissioning Record must be filled out and a copy returned to RA Tech UK Ltd at time of installation, or the registration form found here, must be filled out and submitted from our website within 14 days of the installation date.

        If you have multiple installations on a single project, you can group the entire installation into one project application

        In subsequent years, the tundish must have the annual service checks and subsequent service records filled out by a competent engineer, to continue to validate the conditional warranty.

        When installed in compliance with the installation instructions, is registered and has all of its relevant annual service checks, all hotun dry trap tundishes are warranted for a period of 10 years for any manufacturing fault or defect.

        The customer should be given the signed “Installation, Commissioning and Service Records” found on the installation leaflet at the completion of the installation.

        Please follow this link to download a printable copy of the hotun range installation, operation, service and warranty instructions

        In the unlikely event that the product develops a manufacturing fault during this period, in the first instance, please send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the issue with the product, or call us on 01332 702678.

        To register your hotun detect alarm unit, please fill out our online registration form here

        Warranty Claims Procedure

        If you think you have a faulty product, please fill out our hotun detect Warranty Claims Form or send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim hotun detect” stating the date of purchase (with proof) and let us know what has gone wrong. Alternatively, you could call us on (01332) 702678 and speak to one of our team.

        *(if registered – conditions apply)

        hotun SF dry trap tundish is WRAS approved

        WRAS Approved product

        hotun SF WRAS approval information:

        WRAS Approval Number: 250404708

        WRAS Approval Documents:

        WRAS certificate SF range 29187 

        WRAS Approval Certificate SF range Number 25040708

         

         

         

        Downloads & Information

        Everything You Need

        Product information, technical data and installation examples all in one place.

        Point Of Sale Leaflet

        Download PDF

        Product Guide

        Download PDF

        Featured Installations

        View Projects

        Upgrade With hotun detect & hotun detect remote

        Need Additional Discharge Detection?

        The hotun hiflo SF dry trap tundish can be upgraded with hotun detect & detect remote, providing an audible and visual alert when water begins to discharge through the tundish

        You May Also Like

        Customers Also Bought

        Other popular hotun products trusted by installers across the UK.

        Real Installations

        Trusted. Installed.

        See how installers across the UK are using the hotun hiflo SF dry trap tundish in real-world systems. Browse our featured installations for inspiration.

        Louis Allen - Installation using hotun SF

        Louis Allen

        LA Plumbing
        Sam Watt - Installation using hotun SF

        Sam Watt

        SW Gas Works
        Installation using hotun hiflo 100c white 15/32

        Ryan Nicholson

        DC Heating
        Dan Ragan - Installation using hotun SF

        Dan Ragan

        Dragan Plumbing & Heating

        Product Resources

        Downloadable Images

        Download high-quality product images.

        Product Selector Guide

        Discover The Right hotun Solution For Your Requirements

        Use the product selector to quickly identify the most suitable hotun solution for your application.

        1. Select your installation type
        Choose the option that best matches your boiler or heating system.

        2. Select the required temperature
        This helps determine which hotun product is suitable for your installation.

        3. View your recommended product
        The selector will guide you towards the appropriate product and provide further information.

        Need help choosing?
        If you’re unsure which product you need, contact our technical team for assistance.

        Question 1

        What are you looking for?

        Select the option that best describes what you need.

        Question 2

        What system is the tundish being used with?

        This helps us identify the appropriate tundish range.

        Question 3

        What connection size do you require?

        Choose the connection size, or select unsure if you need help identifying it.

        Question 2

        Where do you want the discharge alarm?

        Choose where you want the alarm to be heard.

        Question 3

        Would you like detection at the installation as well?

        hotun detect provides audible and visual indication of water discharge.

        Question 2

        Which protection do you require?

        Select the application or range you are working with.

        Question 3

        Would you like discharge detection too?

        Add hotun detect to provide audible and visual warning of water discharge.

        Question 2

        How many discharge pipes are you connecting?

        This helps identify the appropriate condensate solution.

        Question 3

        Would you like discharge detection too?

        Add hotun detect if you want audible and visual warning of water discharge.

        Your result

        Your recommended hotun solution

        Based on your answers, the following hotun products form the suggested solution for your installation.

        Recommended hotun products

        Find your nearest hotun stockist

        Enter your postcode and we'll take you straight to the hotun Store Locator.

        Please enter your postcode.