hotun SF 15x22mm Dry Trap Tundish

15mm Push-Fit Dry Trap Tundish with 22mm Outlet

PATENTED, PIONEERING PRODUCTS 

Compact dry trap protection for low volume discharges

The hotun SF 15x22mm dry trap tundish is designed to manage low-volume discharges from heating and water systems. It combines a tundish with a dry trap to provide a visible discharge point while helping prevent unwanted odours from escaping through the waste pipe.

Suitable for a range of applications, the hotun SF provides a practical solution for installations where pressure relief valve (PRV) discharges and other low volume water releases need to be safely managed.

Suitable Applications for the hotun SF

The hotun SF 15x22mm dry trap tundish is suitable for a variety of low-volume discharge applications, including:

  • Boilers fitted with pressure relief valves (PRVs) only.
  • Heat Interface Units (HIUs).
  • Small unvented water heaters with a capacity of less than 15 litres.
  • Fan Coil Unit (FCU) drip trays.
  • Mechanical Ventilation with Heat Recovery (MVHR) drip trays.
  • Water tank overflows, when used in conjunction with a compatible alarm system.

Always check the appliance manufacturer’s instructions and relevant installation requirements to confirm suitability.

Connections, Specifications and Flow Rate

The hotun SF features a 15mm inlet with an integrated, temperature-compliant push-fit connection and an outlet suitable for 22mm copper or 21.5mm plastic pipework, with a 22mm compression nut and olive supplied. It offers a rated flow rate of 16 LPM and a maximum flow rate of 22 LPM when installed with optimised pipework, including 200mm of straight pipe before the tundish.

Installation Requirements and Compatibility

For unvented water heaters fitted with temperature and pressure relief valves (T/PRVs), all downstream D2 discharge pipework and soil pipes must be suitably rated for water discharging at 90–95°C.

Appliances fitted with PRVs only, such as boilers and water heaters with a capacity below 15 litres, do not have the same D2 waste pipe temperature requirement. However, the appliance manufacturer’s specifications and applicable installation requirements must always be followed.

The hotun SF dry trap tundish provides a compact, versatile solution for managing low-volume discharges, with the added benefit of compatibility with the hotun detect and hotun detect remote for improved discharge monitoring.

 View all products in the hotun SF range here

 

Key Product Information

About hotun SF Dry Trap Tundish 

Key product information at a glance.

Key Features

  • Approved under WRAS Approval Number 250404708, supporting compliance with relevant water regulations.
  • Unique open-sided design allows visibility of both flowing and residual water, helping with fault diagnosis and routine inspection.
  • Compatible with hotun detect and hotun detect remote. Supports discharge monitoring with an audible alarm to help identify potential PRV discharge issues, including where remote notification is useful.
  • Rated for use up to 120°C, making it suitable for applications requiring a temperature-rated dry trap tundish.
  • Features an A2 stainless steel spring and bolt, plus a high-quality, moulded drainage-grade EPDM rubber valve.
  • Quick push-fit installation with the integrated collet insert allows quick connection to compatible D1 pipework.
  • Provides a rated flow of 16 LPM and a maximum flow of 22 LPM with optimised pipework.
  • Developed to meet relevant Water and Building Regulation requirements when installed in accordance with the manufacturer’s instructions.

Key Benefits

  • Long-term reassurance with a 10 year conditional warranty when installed and maintained in accordance with the warranty terms.
  • Easy maintenance due to it being able to be inspected and cleaned in situ without removing or dismantling the tundish.
  • Helps prevent foul smells from the waste system entering the building while allowing visible discharge from the relief valve.
  • Designed to provide protection against backflow contamination and back-siphonage when correctly installed.

Click either image to enlarge in a new page

Typical pipework arrangement when using a hotun dry-trap tundish with a boiler connected to the condensate discharge pipe

Diagram showing typical boiler PRV discharge into hotun tundish to foul drain pipe or condensate pump arrangement with a hotun dry trap tundishTypical pipework arrangement when using a hotun dry-trap tundish with a boiler connected to the condensate discharge pipe

Diagram of Typical pipework arrangement when using a hotun dry-trap tundish with a small unvented water heater

 Inlet Pipe Size

 15mm (or 1/2″ for imperial applications)

 Inlet Connection

 15mm Inbuilt temperature compliant push-fit connection

 Outlet Pipe Size

 22mm Copper or 21.5mm plastic 

 Outlet Connection

 22mm Compression nut and olive (supplied)

 Rated Flow Rate

 16LPM

 Max Flow Rate

 22LPM (with optimised pipework – 200mm straight pipe before tundish see optimised diagrams below)

 Usual Applications

  • Small (<15L capacity) water heaters
  • Boilers with PRV’s only (unless otherwise stated by a boiler manufacturers specification/instructions)
  • HIU’s

NB

1. For unvented water heaters fitted with T/PRV’s, all D2 downstream pipework and soil pipes must be suitably rated for water discharging at 90-95°C.

2. Appliances with PRV’s only (ie boilers and water heaters of less than 15L capacity) do not have a D2 waste pipe temperature requirement

10 Year Standard Warranty*

RA Tech UK Ltd provides a 10 Year Conditional Warranty, the installer must register the product within 14 days of the installation date. Failure to register the product and carry out the annual service may invalidate the warranty.

A copy of the Installation Commissioning and Warranty Instructions MI 2024 v1.3a and Commissioning Record must be filled out and a copy returned to RA Tech UK Ltd at time of installation, or the registration form found here, must be filled out and submitted from our website within 14 days of the installation date.

If you have multiple installations on a single project, you can group the entire installation into one project application

In subsequent years, the tundish must have the annual service checks and subsequent service records filled out by a competent engineer, to continue to validate the conditional warranty.

When installed in compliance with the installation instructions, is registered and has all of its relevant annual service checks, all hotun dry trap tundishes are warranted for a period of 10 years for any manufacturing fault or defect.

The customer should be given the signed “Installation, Commissioning and Service Records” found on the installation leaflet at the completion of the installation.

Please follow this link to download a printable copy of the hotun range installation, operation, service and warranty instructions

In the unlikely event that the product develops a manufacturing fault during this period, in the first instance, please send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the issue with the product, or call us on 01332 702678.

To register your hotun detect alarm unit, please fill out our online registration form here

Warranty Claims Procedure

If you think you have a faulty product, please fill out our hotun detect Warranty Claims Form or send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim hotun detect” stating the date of purchase (with proof) and let us know what has gone wrong. Alternatively, you could call us on (01332) 702678 and speak to one of our team.

*(if registered – conditions apply)

hotun SF dry trap tundish is WRAS approved

WRAS Approved product

hotun SF WRAS approval information:

WRAS Approval Number: 250404708

WRAS Approval Documents:

WRAS certificate SF range 29187 

WRAS Approval Certificate SF range Number 25040708

Downloads & Information

Everything You Need

Product information, technical data and installation examples all in one place.

Point Of Sale Leaflet

Download PDF

Product Guide

Download PDF

Featured Installations

View Projects

Upgrade With hotun detect & hotun detect remote

Need Additional Discharge Detection?

The hotun SF dry trap tundish can be upgraded with hotun detect & detect remote, providing an audible and visual alert when water begins to discharge through the tundish

You May Also Like

Customers Also Bought

Other popular hotun products trusted by installers across the UK.

Real Installations

Trusted. Installed.

See how installers across the UK are using the hotun SF dry trap tundish in real-world systems. Browse our featured installations for inspiration.

Louis Allen - Installation using hotun SF

Louis Allen

LA Plumbing
Sam Watt - Installation using hotun SF

Sam Watt

SW Gas Works
Installation using hotun hiflo 100c white 15/32

Ryan Nicholson

DC Heating
Dan Ragan - Installation using hotun SF

Dan Ragan

Dragan Plumbing & Heating

Product Resources

Downloadable Images

Download high-quality product images.

Product Selector Guide

Discover The Right hotun Solution For Your Requirements

Use the product selector to quickly identify the most suitable hotun solution for your application.

1. Select your installation type
Choose the option that best matches your boiler or heating system.

2. Select the required temperature
This helps determine which hotun product is suitable for your installation.

3. View your recommended product
The selector will guide you towards the appropriate product and provide further information.

Need help choosing?
If you’re unsure which product you need, contact our technical team for assistance.

Question 1

What are you looking for?

Select the option that best describes what you need.

Question 2

What system is the tundish being used with?

This helps us identify the appropriate tundish range.

Question 3

What connection size do you require?

Choose the connection size, or select unsure if you need help identifying it.

Question 2

Where do you want the discharge alarm?

Choose where you want the alarm to be heard.

Question 3

Would you like detection at the installation as well?

hotun detect provides audible and visual indication of water discharge.

Question 2

Which protection do you require?

Select the application or range you are working with.

Question 3

Would you like discharge detection too?

Add hotun detect to provide audible and visual warning of water discharge.

Question 2

How many discharge pipes are you connecting?

This helps identify the appropriate condensate solution.

Question 3

Would you like discharge detection too?

Add hotun detect if you want audible and visual warning of water discharge.

Your result

Your recommended hotun solution

Based on your answers, the following hotun products form the suggested solution for your installation.

Recommended hotun products

Find your nearest hotun stockist

Enter your postcode and we'll take you straight to the hotun Store Locator.

Please enter your postcode.