hotun shield 100c
Tundish Safety Shield for Protection Against Scalding Discharge Water
PATENTED, PIONEERING PRODUCTS
Protecting against scalding water. A new generation of tundish safety
The hotun shield 100c is a dry trap tundish safety shield, the ideal protection device designed to help reduce the risk of accidental or deliberate contact with potentially scalding discharge water. By providing an extra layer of protection around the tundish, it helps reduce the risk of contact with hot water. However, the installer must assess whether a shield is suitable for the specific installation.
Compatibility With hotun Dry Trap Tundishes
The hotun shield 100c is designed for the threaded-inlet hotun 100c range and is compatible with both the hotun 100c 15x22mm dry trap tundish and hotun hiflo 100c 15x32mm dry trap tundish. However, it cannot be used with the SF (Speedfit) range of hotun tundishes.
Understanding The Air Break To Drain Designation
The hotun shield 100c has a solid construction with no free area, unlike an open shield design. As a result, fitting the shield means the hotun 100c dry trap tundish no longer maintains its “Air Break to Drain” designation.
For this reason, the shield is intended for applications where maintaining this designation is not a requirement. Certain water tank overflow applications may be suitable, depending on the specific installation requirements.
Important Backflow Protection Restrictions
The hotun shield 100c must not be used in applications where protection against Category 5 backflow contamination of potable (wholesome) water supplies is required. This means it is unsuitable for applications connected directly to, or supplied with, potable water, including unvented water heaters.
It is important to understand that the shield provides physical protection against contact with hot discharge water; it does not provide Category 5 backflow protection. Therefore, installers must check the requirements of the application carefully before deciding whether to fit the device.
Installer Risk Assessment
Before fitting the hotun shield 100c, the installer should carry out a site-specific risk assessment. This should take into account the location and accessibility of the tundish, the potential risk of contact with hot discharge water and the requirements of the installation.
Ultimately, the installer is responsible for determining whether the hotun shield 100c is suitable for the application. The final installation must also meet all applicable requirements.
Key Product Information
About hotun shield 100c
Key product information at a glance.
Key Features:
- A removable shield that can be fitted on all hotun 100c dry trap tundishes
Key Benefits:
- To prevent deliberate or accidental contact with potentially scalding water dripping/flowing through the open tundish
Important Compatibility Information:
- hotun shield is not suitable for applications that have a direct connection to, or are supplied with, potable/wholesome water, such as unvented water heaters.
|
Product Name: |
hotun shield 100C |
|
Product Type: |
Shielding Device |
|
Product MPN: |
HS100C |
|
Compatibility: |
Note: hotun shield HS100C is only compatible with the hotun 100c range of dry trap tundishes, ie threaded inlet. They are NOT compatible with our SF (pushfit) range of tundishes
10 Year Conditional Warranty*
RA Tech UK Ltd provides a 10 Year Conditional Warranty, the installer must register the product within 14 days of the installation date. Failure to register the product and carry out the annual service may invalidate the warranty.
A copy of the Installation Commissioning and Warranty Instructions MI 2024 v1.3a and Commissioning Record must be filled out and a copy returned to RA Tech UK Ltd at time of installation, or the registration form found here, must be filled out and submitted from our website within 14 days of the installation date.
If you have multiple installations on a single project, you can group the entire installation into one project application
In subsequent years, the tundish must have the annual service checks and subsequent service records filled out by a competent engineer, to continue to validate the conditional warranty.
When installed in compliance with the installation instructions, is registered and has all of its relevant annual service checks, all hotun dry trap tundishes are warranted for a period of 10 years for any manufacturing fault or defect.
The customer should be given the signed “Installation, Commissioning and Service Records” found on the installation leaflet at the completion of the installation.
Please follow this link to download a printable copy of the hotun range installation, operation, service and warranty instructions
In the unlikely event that the product develops a manufacturing fault during this period, in the first instance, please send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the issue with the product, or call us on 01332 702678.
Warranty Claims Procedure
If you think you have a faulty product, please fill out our Warranty Claims Form or send an email to info@ratechuk.co.uk with the subject title of “Warranty Claim” stating the date of purchase (with proof) and let us know what has gone wrong. Alternatively, you could call us on (01332) 702678 and speak to one of our team.
*(if registered – conditions apply)
Downloads & Information
Product information, technical data and installation examples all in one place.
Point Of Sale Leaflet
Product Guide
Technical Specification
Featured Installations
You May Also Like
Customers Also Bought
Real Installations
Trusted. Installed.
See how installers across the UK are using the hotun shield 100C in real-world systems. Browse our featured installations for inspiration.
Alex Davies
Dean Jones
Robert Alan Jamison
Product Resources
Downloadable Images
Download high-quality product images.
Product Selector Guide
Discover The Right hotun Solution For Your Requirements
Use the product selector to quickly identify the most suitable hotun solution for your application.
1. Select your installation type
Choose the option that best matches your boiler or heating system.
2. Select the required temperature
This helps determine which hotun product is suitable for your installation.
3. View your recommended product
The selector will guide you towards the appropriate product and provide further information.
Need help choosing?
If you’re unsure which product you need, contact our technical team for assistance.
What are you looking for?
Select the option that best describes what you need.
What system is the tundish being used with?
This helps us identify the appropriate tundish range.
What connection size do you require?
Choose the connection size, or select unsure if you need help identifying it.
Where do you want the discharge alarm?
Choose where you want the alarm to be heard.
Would you like detection at the installation as well?
hotun detect provides audible and visual indication of water discharge.
Which protection do you require?
Select the application or range you are working with.
Would you like discharge detection too?
Add hotun detect to provide audible and visual warning of water discharge.
How many discharge pipes are you connecting?
This helps identify the appropriate condensate solution.
Would you like discharge detection too?
Add hotun detect if you want audible and visual warning of water discharge.
Your recommended hotun solution
Based on your answers, the following hotun products form the suggested solution for your installation.
Find your nearest hotun stockist
Enter your postcode and we'll take you straight to the hotun Store Locator.












